JSutils for Computer Energy Saving and Energy Use Calculation
Bookmark and Share
Updated: 01-Jul-2010
JSutils Compact Disk

EnCalcGU Formulae

Version: 3.0
Size: 573KB
Released
01-July-2010
EnCalcGU icon
JSutils software logo

EnCalcGU uses the following formulae to calculate the results:

Actual Results

Days

=

Date 2 - Date 1

Number Quarters (1)

=

The number of complete and partial quarters between Date 1 and Date 2

Number Months

=

The number of complete and partial months between Date 1 and Date 2

Units Used (2)

=

( Meter Reading 2 - Meter Reading 1 )

KWHrs Used (3,4)

=

( Units Used * Correction Factor * Calorific Value * Conversion Factor) / 3.6

Rate 1 KWHrs (5,7)

=

The lower value of: KWHr Used and
(Rate 1/2 Break Point * Number Quarters in Date 1 To Date 2 )

Rate 2 KWHrs

=

KWHr Used - Rate 1 KWHr

Rate 1 Cost

=

Rate 1 KWHr * Rate 1 Unit Cost

Rate 2 Cost

=

Rate 2 KWHr * Rate 2 Unit Cost

Total Fixed Charge (7)

=

Fixed Charge * Number Quarters or Months in Date 1 To Date 2

Total Discount 1 (8)

=

FIxed Amount: Discount 1 * ( Number Quarters or Months)

Percentage: ( Normal Rate 1 Cost + Normal Rate 2 Cost + Cheap rate Cost +Total Fixed Charge 1 ) * ( Discount 1 % / 100 )

Total VAT (6)

=

( Normal Rate 1 Cost + Normal Rate 2 Cost + Cheap rate Cost +Total Fixed Charge 1 -Total Discount 1 ) * ( VAT% / 100 )

Total Discount 2 (7)

=

Discount 2 * ( Number Quarters or Months)

Total Cost (7)

=

Normal Rate 1 Cost + Normal Rate 2 Cost + Cheap rate Cost +Total Fixed Charge 1 -Total Discount 1 + Total VAT - Total Discount 2

Cost per Day

=

Total Cost (inc VAT) / Days

KWHrs per Day

=

KWHrs Used / ( Number Days between Date 2 and Date 1 )

CO2 Generated (Kg)

=

(Total of Units Used) * CO2 Conversion Factor

1. See Using EnCalcGU for an explanation of this formula.
2. Works in whole units, any decimals entered will be rounded.
3. Conversion Factor is 1 for cubic metres and 2.8 for 100;s of cubic feet (old style UK meters).
4. The Volume Conversion Factor is also known as the Correction Factor
5. If the Break Point = 0 then Rate 1 KWHr = KWHr Used.
6. If the currency selected is not UK Pounds (£) or Euros ( €) then VAT is changed to TAX.
7. Quarters or Months depends on whether the Monthly checkbox is ticked.
8. Discount 1 can be either a fixed amount or a percentage of the cost before TAX/V.AT

Predicted Results

Predicted Days

=

Date 1 + No Quarters To Predict Forward (This can be less than Actual Days)

Units Used

=

( ( Meter Reading 2 - Meter Reading 1 ) * Predicted Days ) / Actual Days

Rate 1 KWHrs (7)

=

( The lower value of : KWHr Used and
( Rate 1/2 Break Point KWHr * ( Number Predicted Quarters or Months )

Rate 2 KWHr

=

KWHr Used - Rate 1 KWHr

Rate 1 Cost

=

Rate 1 KWHr * Rate 1 Unit Cost

Rate 2 Cost

=

Rate 2 KWHr * Rate 2 Unit Cost

Fixed Charge Total (7)

=

Fixed Charge * ( Number Predicted Quarters or Months )

Total Discount 1 (7)

=

Discount 1 * ( Number Predicted Quarters or Months)

Total VAT (6)

=

( Normal Rate 1 Cost + Normal Rate 2 Cost + Cheap rate Cost +Total Fixed Charge 1 -Total Discount 1 ) * ( VAT% / 100 )

Total Discount 2 (7)

=

Discount 2 * ( NumberPredicted Quarters or Months)

Total Cost (6)

=

Normal Rate 1 Cost + Normal Rate 2 Cost + Cheap rate Cost +Total Fixed Charge 1 -Total Discount 1 + Total VAT - Total Discount 2

CO2 Generated (Kg)

=